Fire-Rated Inspection Hatch, Non-Hinged | EI30

Fire-Rated Inspection Hatch, Non-Hinged | EI30

Fire rated access panel for use in tight spaces | EI30ESL

This slim hatch is designed for locations with limited space behind the structure or insufficient room for a hinged cover to open. The cover is held to the frame by magnets, with a safety cable to prevent it from falling.

Features | EI30ESL:

  • Material: hot-dip galvanised steel
  • Powder-coated in RAL 9010, fine-textured matt white
  • Installation depth: 40 mm inward from the mounting surface
  • Type-approved for vertical plasterboard and masonry structures
  • Airborne sound insulation tested
  • Custom sizes and colours available to order
  • Made in Finland – Key Flag product
Contact sales
Product codeInstallation opening (mm)
EI30ESL1515150x150
EI30ESL2020200x200
EI30ESL2030*200x300
EI30ESL2050*200x500
EI30ESL2525250x250
EI30ESL3030300x300
EI30ESL3050*300x500
EI30ESL3535*350x350
EI30ESL4040400x400
EI30ESL4060***400x600
EI30ESL5050500x500
EI30ESL5555*550x550
EI30ESL6060***600x600
EI30ESL6080***600x800
EI30ESL6565***650X650
* Check availability
*** Size requires site-specific approval. Check availability

Installation instructions | EI30ESLType approval | EI30ESLClassification report | EI30

Size of the installation opening = nominal size of the hatch
Type-approved dimensions 150×150 ... 550×550 mm.
Outer dimension = nominal size +50 mm
Depth 40 mm inwards from the installation surface

Fit the hatch using fixings suitable for the structure. Opening the hatch requires the fixings to be loosened, so plasterboard anchors, concrete screws or concrete anchors are recommended. ESSVE SAM4 and 5 × 40 mm concrete screws were used in type testing.

Airborne sound insulation tested | SFS-EN ISO 10140-2
EI30ESL3030 / 300×300 - ≥42 dB Dn,e,w[dB]

* Check availability.
*** Check availability; this size also requires approval for the specific building project.